Products- Sino-Galvo (Jiangsu) Technology Co., Ltd.
Welcome to Sino-Galvo (Jiangsu) Technology Co., Ltd.Official website!
MC1603 Monitoring Scanning System

MC1603 High Speed Galvo Scanner motors are introduced from America.

It has good running stability, high positioning accuracy, fast marking speed, strong anti-interference ability, the overall performance of MC1603 has reached the international leading level in this field. 

 

The advantages are as following:


Built-in 13 million pixel camera, positioning accuracy error is only 0.1mm.

With visual positioning module, it can automatically search for the target and calculate the marking position.

Adopted high-performance scanning motor which imported from the America and the international advanced photoelectric sensing technology.

Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.

Drives with advanced detection ability of position and speed, greatly improving the dynamic response performance and scanning speed of the whole system.

Design of overload, over-current and reverse connect protection, making the system running more reliable.

The whole system adopting the Optimization Designing of electromagnetic compatibility, with high signal-to-noise ratio and strong anti-interference ability.

Smaller scanner size, which meets the increasing industrial demands of higher precision and more compact systems.

MC1603 scan head can be integrated into different application systems easily. The housing is very strong and dustproof. Thus it can be used in the extremely bad environment.


MC1603 Technical Parameters

Speed

Marking Speed(1)

4000mm/s

Positioning Speed(1)

4000mm/s

Writing Speed(2)

301cps

Step Response Time(1% of   full scale)

370us

Step Response Time(10% of   full scale)

630us

Tracking Error Time

202us

Precision and Error

Linearity

99.9%

Repeatability (RMS)

8μRad

Gain Error

5mRad

Zero Offset

5mRad

Long-term Drift Over 8   Hours

0.5mRad

Scale Drift

40PPM/℃

Zero Drift

15μRad./

Lens Damage Threshold

K9 Matrix

9.1J/cm^2

Si Matrix

10J/cm^2

Wavelength(3)                                                     

10600nm/1064nm/355nm

Power and Signal

Input Voltage

±15VDC

Rated Current

2A

Interface Signal

XY2-100

Max Machinery Scan Angle(4)

±11°

Working Current, Temperature,   Dimension

Working Temperature

0℃--45℃

Storage Temperature

-10--60

Aperture

10mm

Galvanometer Scanner   Dimension (LxWxH)

134×96.5×120.6mm

Galvanometer Scanner   Weight

≈0.9Kg

Auto-focusing Control Parameters

Measure Solution

Laser Ranging

Measure Resolution

0.01mm

Measure Accuracy

±0.1mm

Laser Wavelength

620~690nm

Single Measurement Time

0.2s

 

Note: The above data are tested after 30 min warm-up

(1) With F-theta objective, F=160mm, marking 2mm height single character

(2) With F-theta objective, F=160mm, marking 1mm height single character per second

(3) Special wavelength coating film can be customized

(4) If any special requirement, customization is available. Factory default value is ±11°